{"id":852,"date":"2026-07-09T17:11:52","date_gmt":"2026-07-09T09:11:52","guid":{"rendered":"https:\/\/www.huiqi-china.com\/?p=852"},"modified":"2026-07-09T17:11:55","modified_gmt":"2026-07-09T09:11:55","slug":"blogs-fountain-noise-solution","status":"publish","type":"post","link":"https:\/\/www.huiqi-china.com\/en\/blogs-fountain-noise-solution\/","title":{"rendered":"How can noise from a residential complex fountain be addressed? The real source of the noise isn't the pump."},"content":{"rendered":"<p>When property management receives a noise complaint, their first instinct is usually to ask the fountain maintenance contractor to \u201dreplace the pump\u201d or \u201dturn off the fountain at night.\u201d Turning it off is certainly effective, but since fountains are often the centerpiece of many residential communities, shutting them down at night detracts from the overall quality of the environment; replacing the pump, on the other hand, often results in wasted money while the noise persists\u2014because the problem isn\u2019t with the pump at all.<\/p>\n\n<p>The purpose of this article is to help property management companies and fountain maintenance personnel identify the sources of noise before taking any action.<\/p>\n\n<p><strong>\u25c6 Direct answer:<\/strong>In most cases, the true source of noise pollution from residential complex fountains is not the water pump itself, but rather structural sound transmission caused by a lack of vibration-damping measures during installation and improper pipe mounting; unreasonable water flow and discharge designs; and noise from auxiliary equipment such as the control panel\u2019s cooling fan. Only by accurately identifying the type of noise and its transmission path can an effective noise reduction solution be selected; blindly replacing the pump often fails to resolve the issue of fountain noise disturbing residents.<\/p>\n\n<h2>The Six Real Sources of Fountain Noise<\/h2>\n\n<p>In actual engineering projects, noise complaints regarding residential complex fountains are concentrated in the following six categories, each of which requires a completely different approach:<\/p>\n\n<ul>\n  <li><strong>Lack of Vibration Damping in Pump Installation:<\/strong>When the pump comes into direct contact with the foundation or piping, vibrations are transmitted and amplified through the structure, which is particularly noticeable in the quiet of the night.<\/li>\n  <li><strong>Pipe Mounting and Resonance:<\/strong>Excessive spacing between pipe anchor points and a lack of vibration-dampening supports cause water flow pulsations to induce pipe resonance, with the sound traveling along the pipeline to the building structure.<\/li>\n  <li><strong>Improper drainage design:<\/strong>Improper design of the angle, height, or landing point of a water column as it falls onto the pool surface or a cascade step can cause a persistent slapping or hollow ringing sound.<\/li>\n  <li><strong>Cavitation and Vaporization in Pipelines:<\/strong>Insufficient pressure at the pump's suction inlet causes cavitation, resulting in a high-frequency noise that sounds like cracking. Prolonged cavitation can also damage the pump impeller.<\/li>\n  <li><strong>Control Panel Cooling Fan:<\/strong>The cooling fans in variable-frequency drives and control cabinets become a noticeable source of noise in the quiet of the night, especially when the fans are worn out or covered in dust.<\/li>\n  <li><strong>Insufficient sound insulation between equipment:<\/strong>The pump room or equipment pit is located too close to the residential building, and the equipment room itself has not been soundproofed, causing noise to radiate directly outward.<\/li>\n<\/ul>\n\n<p>Key Determination Criteria: If complaints focus on a \u201dlow-frequency humming vibration,\u201d it is typically a problem with structural sound transmission (lack of vibration damping); if it is a \u201dgurgling water sound,\u201d it is usually a problem with the drain design; if it is a \u201dhigh-frequency hissing sound,\u201d prioritize checking for cavitation or the control box cooling fan.<\/p>\n<img decoding=\"async\" src=\"https:\/\/www.huiqi-china.com\/wp-content\/uploads\/2026\/07\/\u65f1\u55b7\u5e73\u9762\u8bbe\u8ba1.webp\">\n<h2>What is the decibel limit for fountain noise in residential areas?<\/h2>\n\n<p>Before addressing a complaint, it is helpful to understand the regulatory benchmarks to assess the severity of the issue and determine the priority for handling it.<\/p>\n\n<p>According to the *Standard for Noise Emissions in the Social Living Environment* (GB 22337\u20142008), noise generated by landscape facilities in residential areas must comply with the standards for Class 2 acoustic environmental functional zones:<\/p>\n\n<table>\n  <thead>\n    <tr>\n      <th>Acoustic Zones<\/th>\n      <th>Applicable Scenarios<\/th>\n      <th>Daytime Limits<\/th>\n      <th>Nighttime Limits<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr>\n      <td>Category 0<\/td>\n      <td>Rehabilitation and Convalescence Area<\/td>\n      <td>50 dB(A)<\/td>\n      <td>40 dB(A)<\/td>\n    <\/tr>\n    <tr>\n      <td>Class 1<\/td>\n      <td>Residential, Healthcare, Culture and Education<\/td>\n      <td>55 dB(A)<\/td>\n      <td>45 dB(A)<\/td>\n    <\/tr>\n    <tr>\n      <td>Class 2 (Commonly Used in Residential Areas)<\/td>\n      <td>Mixed-use residential, commercial, and industrial area<\/td>\n      <td>60 dB(A)<\/td>\n      <td>50 dB(A)<\/td>\n    <\/tr>\n    <tr>\n      <td>Category 3<\/td>\n      <td>Industrial Zone<\/td>\n      <td>65 dB(A)<\/td>\n      <td>55 dB(A)<\/td>\n    <\/tr>\n  <\/tbody>\n<\/table>\n\n<p>It is important to note that:<strong>The limit values for nighttime (10:00 p.m. to 6:00 a.m. the following day) are 10 dB(A) stricter than those for daytime.<\/strong>...This is precisely the root cause of why many residential complex fountains\u2014which pose no problem during the day\u2014frequently receive complaints at night: while the total noise level remains the same, the ambient background noise drops significantly, making the fountain noise stand out in relative terms.<\/p>\n\n<p>Note: Even if actual noise measurements fall within the standard range, residents may still file complaints. Regulatory standards represent the minimum requirement for enforcement; they do not serve as grounds for the assumption that \u201dif the levels are below the standard, no action is needed.\u201d The property management\u2019s goal should be to resolve the complaint entirely, not merely to ensure that the measurements comply with the standards.<\/p>\n\n<h2>Troubleshooting Fountain Noise: Follow the Steps\u2014No Detours<\/h2>\n\n<p>When you receive a complaint, don\u2019t rush to take action. First, spend 15\u201330 minutes conducting an on-site investigation to clearly identify the source of the noise before deciding on a course of action.<\/p>\n\n<ol>\n  <li>\n    <strong>Identify the times when noise occurs and the locations of the complaints:<\/strong>Confirm with residents who have filed complaints the times when the noise is most noticeable (daytime \/ evening \/ late at night) and the specific location (which building, which floor), as well as a description of the type of noise (vibration \/ the sound of running water \/ a humming noise \/ high-pitched sounds). Complaints received at different times and from different locations often point to different sources of noise.\n  <\/li>\n  <li>\n    <strong>Check for vibration transmission by touching the equipment while it is running:<\/strong>Touch the pump base, pipe supports, and the walls of the equipment pit with your hand to assess the intensity of the vibration. If the vibration is clearly transmitted to the structural framework, this indicates that the absence or failure of vibration-damping measures is the primary issue. Pay particular attention to whether there are vibration-damping pads under the pump and whether they have aged, hardened, and lost their elasticity.\n  <\/li>\n  <li>\n    <strong>Isolation Test: Shut Down Devices One by One:<\/strong>During the times when residents\u2019 complaints are most intense, shut down each water pump and control panel fan in turn, and verify the change in noise levels at the location of the complaint after each shutdown. This is the most direct method for pinpointing the specific source of the noise. If the noise decreases significantly after turning off a particular pump, that pump is the primary source; if the noise persists even after all pumps have been turned off, the control panel and other auxiliary equipment must be inspected.\n  <\/li>\n  <li>\n    <strong>Check the drain locations and water feature design:<\/strong>In a quiet nighttime setting, walk around the fountain within a 30\u201350-meter radius to determine the direction and intensity of the water impact sounds. If these sounds are the primary source of complaints, inspect the nozzle angles, the locations where water hits the surface, and the pool design to assess whether the noise can be reduced by adjusting the water patterns or lowering the spray height.\n  <\/li>\n  <li>\n    <strong>Check where the piping runs and how it interfaces with the building structure:<\/strong>Inspect the location and condition of the pipe supports along the main pipeline route to verify whether the supports are equipped with vibration-damping pads and whether the pipes are in direct contact with the building structure (floor, walls, columns). When pipes are directly attached to walls or floor slabs, this can cause high-frequency sound transmission through the structure.\n  <\/li>\n<\/ol>\n\n<h2>Specific Solutions for Five Types of Noise Sources<\/h2>\n\n<h3>Issue 1: Lack of or ineffective vibration-damping measures for the water pump<\/h3>\n\n<p>This is the most common source of fountain noise and also the installation detail most often overlooked. The correct procedure is:<\/p>\n\n<ul>\n  <li><strong>Rubber Vibration-Damping Pads:<\/strong>Rubber vibration-damping pads should be installed between the pump base and the foundation. The hardness of the pads must be appropriate for the weight of the pump; pads that are too soft or too hard will not effectively dampen vibrations. These pads typically last 3\u20135 years and must be replaced once they age and harden.<\/li>\n  <li><strong>Spring Isolators:<\/strong>For pumps with higher power ratings (11 kW or more) or those installed within building structures (such as underground equipment rooms or basements), it is recommended to use spring isolators instead of rubber pads, as they provide more stable vibration isolation.<\/li>\n  <li><strong>Flexible Pipe Fitting:<\/strong>Use rubber flexible connectors (flexible joints) at the connections between the pump\u2019s inlet and outlet and the piping to block the path through which pump vibrations are transmitted to the piping. This is a detail that contractors often overlook, but it is crucial for reducing structural sound transmission.<\/li>\n<\/ul>\n\n<h3>Question 2: Pipe Mounting and Resonance<\/h3>\n\n<ul>\n  <li><strong>Increase the density of fixed brackets:<\/strong>Excessively wide spacing between pipe supports (typically exceeding 1.5 meters) can easily cause pipe resonance. Increase the number of supports and install rubber vibration-damping bushings between the supports and the pipes.<\/li>\n  <li><strong>Eliminating Hard Contact Points:<\/strong>Inspect the points where pipes come into contact with any building structures to ensure that the contact surfaces are isolated with vibration-damping material; pipes must not rest directly on concrete or steel structures.<\/li>\n  <li><strong>Pipeline Route Optimization:<\/strong>Whenever possible, the pipeline route should avoid running parallel to or close to the exterior walls of residential buildings to minimize the surface area through which sound is transmitted into the building structure.<\/li>\n<\/ul>\n\n<h3>Question 3: The drainage design is unreasonable<\/h3>\n\n<ul>\n  <li><strong>Reducing the Spray Height:<\/strong>At night (after 10:00 p.m.), the main spray height is reduced by 30\u201350%, significantly decreasing the water flow velocity and impact force, and correspondingly reducing the sound of falling water. The system automatically switches to night mode via a timed control program, requiring no manual intervention.<\/li>\n  <li><strong>Change the drain location:<\/strong>Adjust the spray nozzle angle so that the water stream hits an area below the water surface\u2014rather than the center of the hard pool floor\u2014to significantly reduce the sound of the water hitting the water surface.<\/li>\n  <li><strong>Increase the water depth:<\/strong>As the water depth in the pool increased to more than 30 cm, the water column was cushioned more effectively upon entry, and the splashing sound was significantly reduced.<\/li>\n  <li><strong>Noise-Reducing Design for Drop Steps:<\/strong>For cascading fountains, a gentle slope or stacked stones should be installed at the end of the steps to dissipate energy and reduce the noise caused by the direct impact of the water flow.<\/li>\n<\/ul>\n  <img decoding=\"async\" src=\"https:\/\/www.huiqi-china.com\/wp-content\/uploads\/2026\/07\/\u97f3\u4e50\u55b7\u6cc9\u7ef4\u62a4.webp\">\n<h3>Question 4: Cavitation in Pipelines<\/h3>\n\n<p>The high-frequency noise caused by cavitation has a characteristic \u201dpopping\u201d or \u201dcracking\u201d sound, and the pump's efficiency drops significantly. Solutions:<\/p>\n\n<ul>\n  <li>Check whether the water pressure at the pump\u2019s suction inlet meets the pump\u2019s required net positive suction head (NPSHr) requirement, a parameter clearly specified in the pump selection documentation.<\/li>\n  <li>Verify that the pump\u2019s installation depth meets the requirements; the minimum submersion depth for a submersible pump is typically 0.5 meters above the top of the pump housing.<\/li>\n  <li>Check the inlet pipe for blockages or localized pressure drops caused by a reduction in cross-sectional area.<\/li>\n  <li>If the water level in the pool is frequently low, the water replenishment control system should be optimized to ensure that the water level remains stable within a safe range.<\/li>\n<\/ul>\n\n<h3>Question 5: Control Panel Cooling Fan<\/h3>\n\n<ul>\n  <li><strong>Clean the cooling fan and filter:<\/strong>Dust buildup is the most common cause of increased fan noise; cleaning the fan once a quarter can keep the noise at a normal level.<\/li>\n  <li><strong>Replacing a Worn-Out Fan:<\/strong>Noise levels increase significantly when the bearings of cooling fans wear out; since replacement is inexpensive, they should be inspected regularly as part of the maintenance schedule.<\/li>\n  <li><strong>Soundproofing of the Control Cabinet:<\/strong>Applying sound-absorbing material to the inner walls of the control box and enclosing the installation area with soundproofing barriers are systematic solutions for addressing noise from the cooling fan.<\/li>\n<\/ul>\n\n<h2>Quick Reference Chart for Fountain Noise Solutions<\/h2>\n\n<table>\n  <thead>\n    <tr>\n      <th>Description of Noise Types<\/th>\n      <th>Possible Sources<\/th>\n      <th>Priority Investigation Actions<\/th>\n      <th>Level of Difficulty<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr>\n      <td>Low-frequency humming \/ sensation of vibration<\/td>\n      <td>Lack of vibration damping for the pump; sound transmission through the piping structure<\/td>\n      <td>Touch-Based and Pipeline Inspection Vibrations<\/td>\n      <td>Can be processed on-site<\/td>\n    <\/tr>\n    <tr>\n      <td>The sound of water splashing<\/td>\n      <td>The drainage design is inadequate, and the water level is too low.<\/td>\n      <td>Nighttime on-site listening test to determine the direction of the water ingress point<\/td>\n      <td>Water type needs to be adjusted<\/td>\n    <\/tr>\n    <tr>\n      <td>High-pitched sizzling \/ crackling sound<\/td>\n      <td>Cavitation, Cooling Fan<\/td>\n      <td>Shutdown Control Box Fan Isolation Test<\/td>\n      <td>Requires professional judgment<\/td>\n    <\/tr>\n    <tr>\n      <td>Directional Sound Transmission<\/td>\n      <td>Hard Contact Between Pipes and Building Structures<\/td>\n      <td>Inspect the contact points along the pipeline route<\/td>\n      <td>Can be processed on-site<\/td>\n    <\/tr>\n    <tr>\n      <td>The overall ambient noise level is relatively high.<\/td>\n      <td>Insufficient sound insulation between equipment units<\/td>\n      <td>Assess the Distance Between the Equipment Room and the Building<\/td>\n      <td>Projects Requiring Renovation<\/td>\n    <\/tr>\n  <\/tbody>\n<\/table>\n\n<h2>Night Mode: A Low-Cost Yet Highly Effective Management Tool<\/h2>\n\n<p>Even after implementing all vibration-damping and noise-reduction measures, the relative perceived intensity of fountain noise remains higher at night in quiet environments than during the day. Setting up an automatic nighttime operation mode is the most practical solution for completely eliminating complaints about fountain noise disturbing residents at night, without compromising the landscape effect during the day.<\/p>\n\n<p>Recommended settings for a typical night mode:<\/p>\n\n<ul>\n  <li><strong>After 10:00 p.m.:<\/strong>Reduce the main spray height to 40\u201350% of the daytime level; turn off the high-noise water features (high-flow main sprays and water cannon-style nozzles), while retaining the low-flow decorative water features and lighting effects.<\/li>\n  <li><strong>After 11:00 p.m.:<\/strong>Depending on the actual conditions of the residential complex, the fountain can be shut down completely, with only the underwater lighting effects remaining.<\/li>\n  <li><strong>06:00 Resume:<\/strong>Automatically switches back to normal daytime operation mode.<\/li>\n<\/ul>\n\n<p>This solution is implemented through a PLC control program that runs on a schedule, requiring no manual intervention, and can be flexibly adjusted based on holidays and seasons.<\/p>\n\n<h2>Frequently Asked Questions (FAQ)<\/h2>\n\n<h3>Complaints About Fountain Noise: Does the Property Management Company Have Any Legal Liability?<\/h3>\n\n<p>Yes. According to Article 294 of the Civil Code, owners of real property shall not discharge noise or other harmful substances in violation of national regulations. As the entity responsible for facility operations, the property management company is liable; if the measured noise levels from the fountain exceed the limits specified in the *Environmental Noise Emission Standards for Social Life* (GB 22337\u20142008), residents have the right to demand corrective action and may also file a complaint with the ecological and environmental authorities. Even if noise levels fall within the standard limits, the property management company has a duty to address residents\u2019 concerns and implement reasonable noise-reduction measures.<\/p>\n\n<h3>What material should be used for vibration-damping pads? What is the difference between rubber pads and spring isolators?<\/h3>\n\n<p>Rubber vibration-isolation pads are suitable for small- and medium-power water pumps (up to 11 kW). They are cost-effective and easy to install, with vibration isolation efficiency typically ranging from 70\u201385%. They have a service life of 3\u20135 years and require periodic inspection for signs of aging or hardening. Spring isolators are suitable for high-power water pumps or equipment installed within building structures. They can achieve vibration isolation efficiency of 90% or higher and are particularly effective at isolating low-frequency vibrations compared to rubber pads. They also have a longer service life, though their initial cost is higher. For typical residential fountain applications (submersible pumps ranging from 0.75 to 7.5 kW), high-quality rubber vibration-damping pads combined with flexible couplings can usually resolve most vibration-induced noise issues.<\/p>\n\n<h3>The fountain has already been built. Is it still possible to retrofit it with vibration-damping measures?<\/h3>\n\n<p>Yes, and in most cases, the retrofit is not complicated. The vibration-damping retrofit for submersible pumps is relatively simple: drain the water, remove the pump, add vibration-damping pads to the base or secure it with vibration-damping brackets, replace the flexible connectors at the inlet and outlet, and reinstall the pump. This can typically be completed in half a day to a full day. Vibration-damping modifications to piping require inspecting and addressing each section of the fixed supports; the scope of work depends on the size of the piping system. It is recommended to entrust a professional fountain maintenance team with the modifications to ensure that the selection of vibration-damping materials and installation methods meet engineering requirements.<\/p>\n\n<h3>Will lowering the spray height affect the aesthetic appeal? Will homeowners accept the night mode?<\/h3>\n\n<p>This depends on the extent of the adjustment and the water feature design. Reducing the nighttime spray height by 30\u201350% typically has a limited impact on the landscape\u2014the visual focus at night is on the lighting effects, while the water feature serves merely as a backdrop. Based on practical experience, most residential communities have shown a high level of owner acceptance after implementing a low-power nighttime mode. In particular, compared to \u201dturning off the fountain,\u201d an operation plan that retains lighting while reducing water volume provides a landscape experience that is closer to normal. It is recommended to explain the details and reasons for the changes to owners in writing before implementing the adjustment plan; transparent communication is more likely to gain acceptance than making changes without explanation.<\/p>\n\n<h3>What is the normal range for noise emitted by the water pump itself?<\/h3>\n\n<p>Commercial submersible pumps from reputable brands typically operate at noise levels between 55 and 70 dB(A) under normal operating conditions (measured 1 meter from the pump body), with specific values directly related to the pump\u2019s power rating. If the actual measured noise level is significantly higher than this range, possible causes include: a damaged or clogged impeller, worn bearings, cavitation, or the pump operating under excessive load. In these cases, the pump itself does indeed require repair or replacement, rather than merely vibration-damping measures.<\/p>\n\n<p>Huiqi Fountains has been deeply involved in the fountain industry for 19 years. During the equipment selection and installation planning phases, vibration damping, sound insulation, and nighttime operation modes are all included as standard features, effectively controlling the risk of fountain noise disturbances to residents from the source. We provide comprehensive control programs and operation and maintenance manuals for all projects, enabling property management teams to independently adjust nighttime operating modes and perform routine maintenance. If you are handling noise complaints regarding a residential community fountain or need to evaluate noise-reduction retrofit options for an existing fountain, please feel free to contact our engineering team at 18818738142.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u7269\u4e1a\u63a5\u5230\u566a\u97f3\u6295\u8bc9\uff0c\u7b2c\u4e00\u53cd\u5e94\u901a\u5e38\u662f\u627e\u55b7\u6cc9\u7ef4 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":854,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"normal-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-852","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-fountain-news"],"_links":{"self":[{"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/posts\/852","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/comments?post=852"}],"version-history":[{"count":1,"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/posts\/852\/revisions"}],"predecessor-version":[{"id":855,"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/posts\/852\/revisions\/855"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/media\/854"}],"wp:attachment":[{"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/media?parent=852"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/categories?post=852"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.huiqi-china.com\/en\/wp-json\/wp\/v2\/tags?post=852"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}